Coating thickness gauge Cpad T400

Measuring range:0~1250μm

Precision value for:%

Storage and interface:Wi-fi connection

Continuous working time:200 Hours

Instrument turnning:260g

The product gross weight:

Product can be colors:black

Appearance size:163*80*35mm

  • Total above
  • Technical
  • The basic
  • Optional
  • The relevant data

1) WI-FI function

2) Finger touch screen

3) Uses magnetic and eddy current thickness measurement method can measure the magnetic metal substrate thickness of the non-conductive coating thickness of non-magnetic coating layers can be measuring non-magnetic metal substrates;

4) You can use two kinds of probes (F1, N1);

5) With two measurements: continuous measurement mode (CONTINUE) and the single measurement mode (SINGLE)

6) Has two operating modes: direct mode (DIRECT) and group means (AB)

7) There are five statistics: the average (MEAN), the maximum (MAX), minimum (MIN), the number of tests (NO.), standard deviation (S.DEV);

8) Both methods can be used to calibrate the instrument and basic calibration method to probe the system error correction

9) Storage function: 500 measurements for storage

10) Delete function: a single measure that appears suspicious data delete, delete all the data can also be stored in the region, in order to carry out new measurements

11) Threshold Setting: measured value outside of the gauge automatic alarm

12) Beep alerts during operation

13) 2 Ways for power off : Automatic and Hand movement

Perfomance

Measuring Range

F400:0~400μm N400:0~400μm F1:0~1250μm F1/90:0~1250μm N1:0~1250μm F10:0~10000μm

CN02:10~200μm

Accuracy

F400、N400 Probe

One point calibration: (2%+0.

7)

Two point calibration:±(1%+0.

7)

F1、F1/90、N1、CN02 Probe

One point calibration:±(2%+1) Two point calibration:±(1%+1)

F10 Probe

One point calibration : ±

(2%+10)

Two point calibration±(1%+10

Calibration method

One point calibration / two point

calibration / Basic Calibration

Resolution

0.1μm(0-99.9μm)

1μm (over100μm)

Weight

300g

Working Environment

Temperature : 0 ℃ ~50 ℃

Humidity:20%~90%

Operation

Operation Mode

Direct testing & Group testing

Measuring mode

Continuous measurement / single

measurement

Power Off

Manual/Auto

Operation Indecation

Musical tones for error

Signal Processing

Limit of Threshold

Auto alarm for values out of limit

Signal Processing

The histogram can be used to

analyze a batch of measurements

Stastis Function

(MEAN)/(S.DEV)/(No.)/(MAX)

/(MIN)

Memory

Thickness Values

500data

Delete

All data within a single suspicious

data / group

Input/Output

Communication

Wi-fi

Electronic Power

Battery

Commercial NiMH / alkaline

batteries 1.5V

Power Indication

Low Voltage indication

Standard Package

Main body 1

Probe(N1 or F1) 1

Calibration foil set 5

base 1

Manual 1

Optional Accesories

Probe

F400/ N400/ F10/ CN02/ F1/90

Probe Mode

F400

F1

F1/90

F10

N400

N1

CN02

Working Principle

Magenetic Permeability

Method

Eddy Current Method

Mesuring range

 

0~400

 

0~1250

 

0~10000

0~400

0~1250

10~200

( Copper covered with

chomium 0~40)

Resolution (mm)

0.1

0.1

10

0.1

0.1

1

Tolera (mm)

One point

calibration(mm)

±(3%H+0.7)

±(3%H+1)

±(3%H+10)

±(3%H+0.7)

±(3%H+1.5)

±(3%H+1)

Tne point

calibration( m)

±(1%H+0.7)

±((1%H+1)

±(1%H+10)

±(1%H+0.7)

±(1%H+1.5

--------

Meas

The minimum

1

1.5

Straig

10

1.5

3

Straig

Straight

uring

Cond ition

radius of

curvature(mm)

 

 

 

ht

 

 

 

 

ht

Only

The minimum

area diameter(mm)

 

F3

F7

 

F7

 

F4

 

F4

 

F5

 

F5

 

F7

The critical thickness of the

matrix(mm)

 

0.2

0.5

 

0.5

 

2

 

0.3

 

0.3

 

0.3

 

Unlimited

Standard:

Main body 1

Probe(N1 or F1) 1

Calibration foil set 5

base 1

Manual 1

Optional Accesories

Probe

F400/ N400/ F10/ CN02/ F1/90

Testing Probe Reference 1

 

base

 

Coating

Organic materials and other non metallic coating (such as: paint

paint enameletc)

Cover thickness < 100mm

Cover thickness > 100mm

Such as magnetic metal iron steel etc.

 

Measuring Area > 30mm

F400: 0~400mm F1 : 0~1250mm

F400 :0~400mm F1    :0~1250mm

F10   :0~10mm

Measuring Area < 30mm

F400: 0~400mm

F1 : 0~1250mm

F400: 0~400mm

Such as

Measuring Area > 10mm

N400 :0~400mm

N400 0~400mm

copper

N1 :0~1250mm

N1 : 0~10mm

aluminum

Measuring Area < 10mm

N400 :0~400mm

N1 : 0~1250mm

tin etc.

N400: 0~400mm


Testing Probe Reference2

 

Probe Coating

Non magnetic metal layer (such as: chromium zinc aluminumcopper tin silver etc.)

Cover thickness < 100mm

Cover thickness < 100mm

Such as magnetic metal iron steel etc.

 

Measuring Area > 30mm

F400: 0~400mm F1: 0~1250mm

F400: 0~400mm F1:    0~1250mm

F10:   0~10mm

Measuring Area < 30mm

F400: 0~400mm

F400:0~400µm

F1: 0~1250mm

Such as copper aluminum tin etc.

Measuring Area > 10mm

Only for copper plating N400: 0~40mm

--------

Measuring Area < 10mm

--------

--------

Plastic non metal base

 

Measuring Area > 7mm

 

CN02: 10~200mm

 

CN02: 10~200mm


About Us
Company profile
News
Corporate philosophy
Teams
Movies
Products
Ultrasonic Thickness Gauge
Coating Thickness Gauge
Hardness Tester
Ultrasonic Nodularity Gauge
Concrete Tester
Surface Roughness Tester
Ultrasonic Flaw Detector
Other NDT Equipment
Surface Roughness Tester
Rockwell Hardness Tester
Technology
Service
Copyright@ 2014-2020 Solid(Beijing) Technology Co.,Ltd All rights reserved.